1.2.2 Warning Labels Warning Labels Meaning You should diligently read this handbook before use machine. The following labels certainly are a. Will not position the device on the sloped floor. Normally the obtainable when the technique machine may well slide, resulting in own harm or maybe the device performs While using the cell malfunction.

The consumer is not really allowed to open up the addresses and panel of your method, neither NOTE: system disassemble is permitted. To make sure the method efficiency and security, only Mindray engineers or engineers approved by Mindray can complete maintenance.

NOTE: On the keep an eye on, the brightness adjustment arrives ahead of distinction. Just after readjusting the check’s contrast and brightness, regulate all preset and peripheral options.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

By continuing your stop by on our website, you will be consenting to our usage of cookies. Nevertheless, you may adjust your cookie configurations Anytime.  Cookie desire Settle for and Carry on

Any time you prevent the scanning as well as graphic capture, you should electricity from the system and disconnect the method in the AC electricity supply, then pull out AC electric power cables. Site 109: Battery Connecting Board

Website page one hundred forty five Cleanse user interface Resources: dry soft fabric, delicate soapy h2o  Approach:  Use dry delicate cloth to wash the surface area with the technique. Should the system is soiled, moisten the soft fabric with gentle soapy h2o and wipe off any stains. Use dry tender cloth to get rid of any humidity and allow all challenging surfaces to completely air-dry. Web site 146: Clean up The Peripherals

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

iZoom™ allows precise viewing of picture from length iWorks™ Protocol helps standardize workflow and decrease Test moments

five.2.three Geometric positioning accuracy Longitudinal geometric positioning accuracy  Exam Step: Do changes as the way in testing the utmost depth. Report the distance by 20mm Every single segment around the longitudinal targets line utilizing the measurement caliper; Pick out the value with the best error (to 20mm), work out the precision utilizing the formula under The measurement caliper needs to be positioned at the higher edge of the target, NOTE:... Web page 79 Transverse geometric Dp50rb login positioning precision  Take a look at Action: Protect the scan area in the phantom with drinking water or pair gel, Carefully Speak to the probe Using the scan floor Regulate the depth, producing the transverse targets being exhibited within the impression. Change the main target level to get posited beside the transverse targets (the normal is not very clear) Alter parameters like acquire, TGC, earning Every transverse targets to get Obviously displayed. Web page eighty five.5.two.4 Blackout Location Check Stage: Go over the scan area from the phantom with h2o or few gel, gently contact the probe Using the scan area Change the depth at a lessen price, and set the main focus at the nearest location to the scan surface. Minimize the value of parameters like AP, Get right up until the background sounds just is often seen. Site eighty one: Software Update And Routine maintenance

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

.. Site 161 The indicator on the printer Mistakes arise once the adapter turns orange, plus the printing printer adapter operates. Disconnect and connect the fails. electrical power adapter, electrical power to the printer adapter again, and verify whether the printing is usual immediately after one minute. Web site 163: Electrical Protection Inspection

Cookies are important to the appropriate operating of the web-site. To increase your working experience, we use cookies to remember log-in aspects and provide protected log-in, gather stats to optimize web-site performance, and deliver information personalized on your interests.

Mindray respects your privacy. We use cookies for a range of uses, such as Web-site performance, improving upon your expertise of our Web-site, developing integration with social websites and supporting focus on our marketing.

NOTE: Be certain that you may pull out and thrust into the IO board sockets vertically when pulling out and assembling the IO board assembly over the posture with the manage. Get rid of panhead screws with washers M3X6 (four) used to protected the IO board, after which you can you might consider out the IO board. Site 116 Get rid of panhead screws with washers (two M3X6) that happen to be fixed on the primary unit, just take out the higher baffle and after that pull out two cables connecting the main board to the power module assembly.